Spot Welding Machine for Dialarc 250 AC/DC wiring question

Spot Welding Machine for Dialarc 250 AC/DC wiring question

Welding Automation for Dialarc 250 AC/DC wiring question

laser Welding Machine for Dialarc 250 AC/DC wiring question

Welding Automation for Dialarc 250 AC/DC wiring question

Welding Automation for Dialarc 250 AC/DC wiring question

Platform Spot Welding Machine for Dialarc 250 AC/DC wiring question

Platform Spot Welding Machine for Dialarc 250 AC/DC wiring question

Dialarc 250 AC/DC wiring question


Tue, 31 Aug 2021 15:25:51 GMT
Bought an older dialarc cheap with no power cord, opened up the panel and the terminal block has no marking for the hot wires. I'm running an 8/3 white, green and black lines. Just wondering which one goes where. Looking forward to firing the old girl up!Sent from my iPhone using Tapatalk
Reply:Take the serial number off the machine (should be on the face plate) and go to Miller's website and download the manual for your machine. The hook up info is in there along with the correct jumper configuration for the input voltage.RogerOld, Tired, and GRUMPYSalesman will call, Batteries not included, Assembly is required, and FREE ADVICE IS WORTH EXACTLY WHAT YOU PAY FOR IT!Dial Arc 250HFThunderbolt 225 AC/DCAssorted A/O torches
Reply:Terminal block should have a row of small (#10) studs and nuts. With one or two jumper bars. Below these should be two 1/4x20 studs. these are the line connections. Should be a third stud or blot next to the terminal board on the bracket or case of welder. Green ground goes here. Look at data plate and see what voltages this welder can be run on.This we tell us how to set the jumpers up. Get the owners manual and it will show you. There are several charts and you have to match he chart to your machine data plate voltage.
Reply:I looked at the manual and there's no ident of L1 or L2. It's set for 230v which is correct.Last edited by rodburner1973; 11-21-2013 at 10:08 AM.
Reply:The manual should look something like this (from a 1979 manual):I can take a pic when I get home if you need.Dave J.Beware of false knowledge; it is more dangerous than ignorance. ~George Bernard Shaw~ Syncro 350Invertec v250-sThermal Arc 161 and 300MM210DialarcTried being normal once, didn't take....I think it was a Tuesday.
Reply:Thanks Minnesotadave! That's exactly what I needed. Mine didn't have or has been worn away from the paper. Sent from my iPhone using Tapatalk
Reply:Make sure yours is not a 575 volt machine. The jumpers line up different and will blow line fuses if set up wrong.  Two basic machines 208/230/460 and 230/460/575.Only your data plate will tell you which you have.
Reply:Ya, not a 575Sent from my iPhone using Tapatalk

Spot Welder for Dialarc 250 AC/DC wiring question,Spot Welding Machine for Dialarc 250 AC/DC wiring question, Laser Welder for Dialarc 250 AC/DC wiring question, Laser Welding Machine for Dialarc 250 AC/DC wiring question,Spot Welder manufacturer in China, Dialarc 250 AC/DC wiring question Laser Welder manufacturer from China
go to see Welding Machine for Dialarc 250 AC/DC wiring question